  Datasheet File OCR Text:
  fkw ... 4 small flange remote seal type pressure transmitter data sheet the fcx ? 2 small flange remote seal type pressure trans- mitter accurately measures gauge pressure and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capaci- tance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and func- tionality. totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. 1. directly connectable to 1-1/2in and 2in flanges the transmitter is connectable to 1-1/2in and 2in pipes without a reducer. 2. connectable to 1/2in and 3/4in pipes use of direct mounting adapter allows the transmitter to be connected to the following process. 1/2in and 3/4in flanges screw connection 1/2-14npt, 3/4-14npt, rc1/2, rc3/4 3. minimum environmental influence the ?loating cell?design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 4. fuji/hart bilingual communications protocol and foundation fieldbus and profibus compatibility fcxa 2 series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart . any hart compatible devices can communicate with fcxa 2 . further, by upgrading electronics founda- tion fieldbus and profibus are also available. features 5. application flexibility various options that render the fcx? 2 suitable for almost any process applications include: analog indicator at either the electronics side or ter- minal side full range of hazardous area approvals built-in rfi filter and lightning arrester 5-digit lcd meter with engineering unit stainless steel electronics housing wide selection of materials high temperature, vacuum seals 6. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 7. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. date EDSX5-82K apr. 3, 2007
fkw ... 4 2 hazardous locations: (note) (1) hhc: hand held communicator functional specifications service: liquid, gas, or vapour span, range, and overrange limit: specifications lower range limit (vacuum limit) ; silicone fill sensor: see fig. 1 fluorinated fill sensor: atmospheric pressure ? onversion factors to different units; 1mpa=10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.9716mmh 2 o=4.01463inh 2 o output signal: 4 to 20ma dc with digital signal super- imposed on the 4 to 20ma signal. power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with op- tional arrester. load limitations: see figure below 2000 [ ? ] 1500 1000 load resistance 500 250 0 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage f kw 25 0 500 ?00 to +500 1.5 {0.5} {5} {? to +5} {15} f kw 3 300 3000 ?00 to +3000 4.5 {3} {30} {? to +30} {45} f kw 4 1000 10000 ?00 to 10000 15 {10} {100} {? to 100} {150} min. max. span limit [kpa]{bar} type overrange limit [mpa] {bar} range limit [kpa]{bar} note: for communication with hhc (model: fxw), min. of 250 ? is required. a tex ex ii 2 gd eex d iic t6 ip66/67 t85 c tamb = -40 c to +65 c eex d iic t5 ip66/67 t100 c tamb = -40 c to +85 c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60 c authorities flameproof iecex scheme /saa ex d iic t5 ip66/67 pending tamb = -40 c to +85 c ex d iic t6 ip66/67 pending tamb = -40 c to +65 c tiis ex do iib+h 2 t4 tamb max = +55 c maximum process temp.=+120 c csa - a tex ex ii 1 gd eex ia iic t5 tamb = -40 c to +40 c eex ia iic t4 tamb = -40 c to +80 c entity parameters: ui=28v, ii=93.3ma, pi=0.66w, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.134mh factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=42.4v, imax=113ma, pi=1w, ci=34.2nf, li=1.134mh authorities intrinsic safety iecex scheme /saa ex ia iic t4 ip66/67 tamb = -40 c to +70 c ex ia iic t5 ip66/67 tamb = -40 c to +50 c entity parameter: ui=28v, ii=93.3ma, pi=0.66w, ci=0.033 f, li=1.034mh tiis ex ia iic t4 tamb max = +60 c entity parameter: ui=28v, ii=94.3ma, pi=0.66w, ci=32.6nf, li=1.134mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, imax=93ma, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit t amb a,b,d y, g , h,s -40 c to +85 c l,p,1,2 y, g , h,s -20 c to +80 c q,s,4,5 y, g , h,s -20 c to +60 c e,f,h y, g , h,s -40 c to +60 c - w,a,d -10 c to +60 c
3 ?utput overscale? adjustable within the range 20.8ma to 21.6ma from hhc (1) ?utput underscale? adjustable within the range 3.2ma to 3.8ma from hhc (1) 3.8 3.2 4 20 20.8 21.6 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout loop-check output: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc (1) . temperature limit: ambient: 15 to +65 c ( 15 to +60 c for arrester option) (?0 to +60 c for fluorinated oil fill transmitter) (?0 to +60 c for silicone oil ?? ?? for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the lim- its specified by each standard. process: zero/span adjustment: zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code ?, p, q , s?. damping: adjustable from hhc or local adjustment unit with lcd display. the time constant is adjustable between 0.12 to 32 seconds. zero elevation/suppression: zero can be elevated or suppressed within the specified range limit of each sensor model. normal/reverse action: selectable from hhc (1) indication: analog indicator or 5-digit lcd meter, as specified. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. ?utput hold? output signal is hold as the value just be- fore failure happens. storage: 40 to +70 c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. note: hhc? version must be more than 6.0 (or fxw 1 3), for fcx- a 2 . lower limit of static press. process temperature atmospheric pressure fill fluid 13th digit of ?ode symbols ?0 to 120 c 0 to 250 c 40 to 120 c 0 to 250 c w, a and d h y and g s fluorinated oil silicone oil 2.7kpa abs {20mmhg abs} tag no. model no. serial no. engineering unit range limit measuring range damping linear square root burnout direction calibration output adjust data self diagnoses printer external switch lock transmitter display linearize rerange items display set vv vv v vv v vv vv vv vv vv vv ? v v vv vv vv vv output mode emc conformity: en61326 a tex ex ii 3 gd eex nl iic t5 tamb = -40 c to +40 c eex nl iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=27nf, li=1.134mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=34.2nf, li=1.134mh eex nal iic t5 tamb = -40 c to +40 c eex nal iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w, model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x authorities t ype n nonincendive iecex scheme /saa - tiis - csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit tamb a,b,d y, g , h,s -40 c to +85 c l,p,1,2 y, g , h,s -20 c to +80 c q,s,4,5 y, g , h,s -20 c to +60 c e,f,h y, g , h,s -40 c to +60 c - w,a,d -10 c to +60 c
fkw ... 4 4 physical specifications electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 x 1.5 conduit, as specified. 1-port (standard) or 2-port with each con- duit, as specified. process connections: jis; 10k, 20k, 30k, 63k ?0, 50a 10k, 20k, 30k, 63k ?5, 20a (with adapter) ansi/jpi; 150lb, 300lb, 600lb, ? 1 /2 ", 2" 150lb, 300lb, 600lb, 1 /2 ", 3 /4 " (with adapter) screw connection (with adapter) ; rc 1 /2 , rc 3 /4 , 1 /2 -14npt, 3 /4 -14npt diaphragm extension: 0, 50, 100, 150, or 200mm as specified. (see model code. extended diaphragm is available only with 316l stainless steel dia- phragm) process-wetted parts material: diaphragm: 316l stainless steel, hastelloy-c monel or tantalum flange face: 316 stainless steel, hastelloy-c lining, monel lining or tanta- lum lining extension: 316 stainless steel (refer to ?ode symbols? non-wetted parts material: electronics housing: low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating (stan- dard), or 316 stainless steel (scs14 per jis g5121), as specified. capillary: in case of 11th code ?. e. l? pvc armored stainless steel. in case of 11th code q . r. s? stain- less steel armored stainless steel. mounting flange: 304 stainless steel or carbon steel, as specified. fill fluid: silicone oil (standard) or fluori- nated oil mounting bracket: 304 stainless steel. environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm (jis 50a) pipe using mount- ing bracket, direct wall mounting mass {weight}: transmitter approximately 10kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 1.5kg per 50mm extension of diaphragm overrange effect: zero shift; 0.2% of url/(1.5 x url) supply voltage effect: less than 0.005% of calibrated span per 1v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) update period: 120 msec * ) step response: time constant: 0.3s * ) dead time: 0.2s * ) (without electrical damping) *) faster response is available as option (maximum update rate: 25 times per second). dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth. insulation resistance: more than 100m ? /500v dc. turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less performance specifications reference conditions, silicone oil fill, ss316 isolating diaphragms, 4 to 20ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability) (standard) for spans greater than 1/10 of url: 0.25% of span for spans below 1/10 of url: (option) (code; 21th digit h) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.2% of upper range limit (url) for 3 years. temperature effect: effect per 28 c change between the lim- its of 15 c and +65 c zero shift: 0.5%/28 c ( x equal to 1/6.5 url or more) zero shift; (0.5 )%/28 c ( x less than 1/6.5 url) total shift; 0.75%/28 c ( x less than 1/6.5 url or more) total shift; (0.25 + 0.5 )%/28 c ( x less than 1/6.5 url) where, x : calibrated span url: m aximum span (upper range limit) note : above specifications are based on the con- ditions that flange and sensor unit are at the same temperature and in the same level. if temperature is different at flange, capillary or sensor unit, output variation may increase. () 0.17+0.08 % of span 0.1 x url span () 0.05+0.05 % of span 0.1 x url span url 6.5 x x url 6.5 x x
5 optional features indicator: a plug-in analog indicator (2.5% accuracy) can be housed in the electronics compart- ment or in the terminal box of the hous- ing. an optional 5-digit lcd meter with engi- neering unit is also available. local adjustment unit with lcd display: an optional 5-digit lcd meter with zero/ span adjustment function, loop-check function and damping adjustment func- tion, is available. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 x 50 s). oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. chlorine service: oil-free procedures as above. includes fluorinated oil for fill. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use on oxygen or chlorine measurement. vacuum and high temperature service: special silicone oil and filling procedure are applied. see fig.1. optional tag plate: an extra stainless steel tag for customer tag data is wired to the transmitter. coating of cell: cell's surface is finished with epoxy/poly- urethane double coating. specify if envi- ronment is extremely corrosive. accessories hand-held communicator: (model fxw, refer to data sheet no. eds8-47) z/s board: parts no.=zzpfcx4-a070 when z/s board is mounted on the fcx a 2 amplifier unit, external adjustment screw will be available for zero and span adjustment. fig. 1 relation between process temperature and operating pressure operating area non-operating area 101 {1010} 53.3 {533} 13.3 {133} 2.7 {27} [kpa abs] {m bar abs} operating pressure ?0 0 60 85 120 200 230 250 process temperature silicone (code y,g) filled liquid: [ c ] silicone (code s) the product conforms to the requirements of the electromagnetic compatibility directive 94/9/ec as detailed within the technical construction file number tn513035. the applicable standards used to demonstrate compliance are : frequency range mhz limits reference standard 30 to 230 40db ( v/m) quasi peak, measured at 10m distance 230 to 1000 47db ( v/m) quasi peak, measured at 10m distance cispr16-1 and cispr16-2 phenomenon test value basic standard performance criteria b electrostatic discharge conducted rf 0.15 to 80mhz 3v 80%am (1khz) electromagnetic field 4kv (contact) 8kv (air) 80 to 1000mhz 10v/m 80%am (1khz) en61000-4-2 burst a en61000-4-3 rated power frequency magnetic field 30a/m 50hz a en61000-4-8 2kv 5khz b en61000-4-4 surge 1.2 s/50 s 1kv (line to line) 2kv (line to ground) b en61000-4-5 a en61000-4-6 emi (emission) en61326 : 1997 class a (standard for industrial location) emi (immunity) en61326: 1997 annex a (standard for industrial location) note) definition of performance criteria a: during testing, normal performance within the specification limits. b: during testing, temporary degradation, or loss of function or performance which is self-recovering.
fkw ... 4 6 g 1 /2 ( 1) 1 /2 - 14npt ( 1) pg13.5 ( 1) m20 1.5 ( 1) g 1 /2 ( 2) 1 /2 - 14npt ( 2) pg13.5 ( 2) m20 x 1.5 ( 2) material size and rating 304 stainless jis 10k 40a steel jis 10k 50a jis 20k 40a jis 20k 50a jis 30k 40a jis 30k 50a jis 63k 40a jis 63k 50a ansi/jpi 150lb 1 1 /2 " ansi/jpi 150lb 2" ansi/jpi 300lb 1 1 /2 " ansi/jpi 300lb 2" y ansi/jpi 600lb 1 1 /2 " ansi/jpi 600lb 2" carbon steel jis 10k 40a jis 10k 50a jis 20k 40a jis 20k 50a jis 30k 40a jis 30k 50a jis 63k 40a jis 63k 50a ansi/jpi 150lb 1 1 /2 " ansi/jpi 150lb 2" ansi/jpi 300lb 1 1 /2 " ansi/jpi 300lb 2" ansi/jpi 600lb 1 1 /2 " ansi/jpi 600lb 2" none 40a, 1 1/2b (wafer type) 50a, 2b direct mounting adapter connection (* 1) 50.......500 ( 0.5...5) 300.....3000 ( 3...30) 1000...10000 (10...100) diaphragm 316l stainless steel 316l stainless steel +au coating hastelloy-c monel tantalum description note note 1 note 2 digit 4 5 6 7 4567 123 f4 0 kw 89 10 11 12 13 14 15 16 17 18 19 20 21 digit no. of code a b c d s t v w 0 1 2 3 4 5 6 7 a b c d e f g h j k l m n p q r s t u v w x y 2 3 4 v a b c d j h m t flange face 316 stainless steel hastelloy-c monel tantalum diaphragm extension (mm) 0 50 100 150 200 0 0 0 0 (* 2) note1: (*1) direct mounting adapter type is specified at 16th to 20th digit. direct mounting adapter is available only for 7th digit code "v". note2: (*2) diaphragm extension is available only for 2" (50a) flanges. combination with 12th digit code "c, e, p, q " are not available. code symbols
7 none (for ordinary locations) tiis, flameproof (conduit seal)(available for 4th digit code "a", "s") tiis, flameproof (cable gland seal)(available for 4th digit code "a", "s") fm, flameproof (or explosionproof)(available for 4th digit code "b", "t") atex, flameproof iecex scheme/saa, flameproof (approval pending) tiis, intrinsic safety fm, intrinsic safety and nonincendive atex, intrinsic safety atex, type n iecex scheme/saa, intrinsic safety fm, combined of flameproof and intrinsic safety mounting bracket capillary armor of capillary stainless steel 1.5m pvc 3m 5m 1.5m stainless steel 3m 5m extra ss tag plate stainless steel elec. housing coating of cell none none none yes none none none yes none yes yes none none none yes yes none yes none yes yes yes yes yes treatment fill fluid standard silicone oil standard fluorinated oil degreasing silicone oil oxygen service fluorinated oil (7th digit code "v", "a", "b", "c" and "d") chlorine service fluorinated oil (7th digit code "h" and "t") high temp. 250 c silicone oil (7th digit code "v", "a", "b", "c", "d" and "h") high temp. and vacuum (250 c) silicone oil (7th digit code "v", "a", "b", "c" and "d") none yes (available for 7th digit code "v", "h", "m" and "t". not available for 5th digit code "y" and 13th digit code "h", "s".) (*4) none 6th digit code "3" cr-mo alloy hexagon socket head cap bolt/ carbon steel nut cr-mo alloy hexagon bolt/carbon steel nut 304 stainless steel bolt/304 stainless steel nut description digit 9 10 11 12 13 14 15 4567 123 f4 kw 89 10 11 12 13 14 15 16 17 18 19 20 21 digit no. of code a b c d x r g h k p t v y b c e m n p q d e l q r s y w g a d h s y c y a b e note3: (*3) customer tag number can be engraved on standard stainless steel name plate. if extra tag plate is required, select "yes". note4: (*4) in case of tropical use, select stainless bolts and nuts. note5: (*5) available for 13th digit code "y, w, g, a, d". 6th digit code "4" note note5 note3 note4 (*3) indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes digital, 0 to 100% none digital, custom scale none digital, 0 to 100% yes digital, custom scale yes digital, 0 to 100% (local adjustment unit with lcd display) none digital, custom scale (local adjustment unit with lcd display) none digital, 0 to 100% (local adjustment unit with lcd display) yes digital, custom scale (local adjustment unit with lcd display) yes a b d e f h l p q s 1 2 4 5 z/s board attached. (*5)
fkw ... 4 8 jis 10k 15a jis 10k 20a jis 20k 15a jis 20k 20a jis 30k 15a jis 30k 20a jis 63k 15a jis 63k 20a ansi/jpi 150lb 1 /2 " ansi/jpi 150lb 3 /4 " ansi/jpi 300lb 1 /2 " ansi/jpi 300lb 3 /4 " ansi/jpi 600lb 1 /2 " ansi/jpi 600lb 3 /4 " screw connection rc 1 /2 screw connection rc 3 /4 screw connection rc 1 /2 - 14npt screw connection rc 3 /4 - 14npt adapter bolts/nuts (* 1) 316 stainless steel cr-mo steel/carbon steel standard long type standard (teflon)(only y, w, g, a and d can be specified on 13th digit). for high temperature (spiral gasket) (only h and s can be specified on 13th digit). (* 2) high accuracy type instruction manual attached instruction manual unattached high accuracy type instruction manual unattached description note note 1 note 2 digit 16, 17 18 19 20 21 4567 123 f4 kw 89 10 11 12 13 14 15 16 17 18 19 20 21 digit no. of code 1 1 2 2 3 3 6 6 1 1 2 2 4 4 s s s s 1 2 1 2 1 2 1 2 h t h t h t r 2 n t w a n 1 2 h l t note1: (* 1) for connection of transmitter receiving pressure unit and direct mounting adapter note2: (* 2) in other option is not necessary, 21st digit code is blank. in case of 21st digit code is blank, instruction manual attached. specifications of direct mounting adapter {for 15, 20a ( 1 /2 , 3 /4 ") connection} and others note 1. when odering the instrument with direct mounting adapter, specify ??in the 5th digit of code symbol, and specify 16th digit to 20th digit. when odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit. 2. unless otherwise described in the specifications, leave the 21st digit blank. ordering infomation when ordering this instrument, specify. 1. code symbols 2. measuring range. 3. output orientation (burnout direction) when abnormality is occurred in the transmitter. hold / overscale (21.6ma) / underscale (3.2ma) unless otherwise specified, output hold function is supplied. 4. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s on 9th digit). 5. tag no. (up to 26 alphanumerical characters), if required.
9 outline diagram (unit:mm) 2-m6 screw depth 9 inner of gasket inner of gasket 105 104 ?0 70 52.5 94.5 88 k 17 231 71 ?9 ?4 m ?8 71 ?9 ?4 ? ?0 8 38 58 (27) 210 ?5 j ?3 g1/2 191 s 60 70 120 20 50 43 20 lt 37 see table 1 + + ck+ + ck connection diagram mtg. pipe jis 50a (2b) u - bolt m8 fastener (flameproof only) cable gland (option) note) ??conduit conn. ??conduit conn. 4 holes 9 dia. with field ind. zero adj. screw earth terminal no flange is attached in case of 5th digit code ?,x? n holes h dia. detail ? detail ? ? up down 105 10 in case of 4th digit code ? in case of 4th digit code ?.b.c.d.e in case of 4th digit code ?.v.w.x 7th digit of code symbols 11th digit of code symbols capillary length [mm] l 5th digit of code symbols 0,g 140 36 4-19 jis-10k-40a 105 1,h 155 36 4-19 jis-10k-50a 120 2,j 140 38 4-19 jis-20k-40a 105 3,k 155 38 8-19 jis-20k-50a 120 4,l 160 42 4-23 jis-30k-40a 120 5,m 165 42 8-19 jis-30k-50a 130 6,n 175 52 4-25 jis-63k-40a 130 7,p 185 54 8-23 jis-63k-50a 145 a,q 127 37.5 4-16 ansi/jpi-150lb-1 1/2b table 1 98.4 b,r 152 39.5 4-20 ansi/jpi-150lb-2b 120.6 c,s 156 41 4-23 ansi/jpi-300lb-1 1/2b 114.3 d,t 165 42.5 8-20 ansi/jpi-300lb-2b 127 e,u 156 42.5 4-23 ansi/jpi-600lb-1 1/2b 114.3 f,v 165 45.5 8-20 ansi/jpi-600lb-2b 127 ? ? ? n-? flange mass approx. [kg] v, h, m, t 0 9.5 a d, q 1500 e, r 3000 l, s 5000 50 10.5 b 100 11.5 c 150 12 d 200 12.5 jkm g1/2 17 8 a, s 1/2-14npt 16 5 b, t pg13.5 84.5 c, v m20 1.5 16 5 d, w 4th digit of the code symbols conduit conn. note) cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. 2-m8 12 note) in case of wafer type, flange is excluded from the scope of supply. mount flange, referring to the view. electronics unit sensor unit
fkw ... 4 10 long vent/drain plug (added specification) n holes h dia. vent/drain plug (t) (6.4) (102) 25 ? ? ?0 ? ?4 88 ?0 52.5 94.5 105 104 231 70 8 t 80 38 58 210 191 70 120 50 60 43 (27) 37 20 s + + ck+ + ck k 17 m ?5 j ?3 g1/2 in case of ansi/jpi-600lb flange mtg. pipe jis 50a (2b) u - bolt m8 fastener (flameproof only) cable gland (option) note) ??conduit conn. ??conduit conn. 4 holes 9 dia. with field ind. zero adj. screw earth terminal connection diagram detail ? detail ? in case of 4th digit code ? in case of 4th digit code ?.b.c.d.e up down 105 10 in case of 4th digit code ?.v.w.x 11th digit of code symbols capillary length [mm] 16th of code symbols 17th of code symbols 1 95 12 4-15 jis-10k-15a 70 2 100 14 4-15 jis-10k-20a 75 1 95 14 4-15 jis-20k-15a 70 2 100 16 4-15 jis-20k-20a 75 1 115 18 4-19 jis-30k-15a 80 2 120 18 4-19 jis-30k-20a 85 1 120 23 4-19 jis-63k-15a 85 2 135 25 4-23 jis-63k-20a 95 h 89 11.5 4-16 ansi/jpi-150lb 1/2b 60.3 t 98 13 4-16 ansi/jpi-150lb 3/4b 69.9 h 95 14.5 4-16 ansi/jpi-300lb 1/2b 66.7 t 117 16 4-20 ansi/jpi-300lb 3/4b 82.5 h 95 14.5 4-16 ansi/jpi-600lb 1/2b 66.7 t 1 1 2 2 3 3 6 6 1 1 2 2 4 4 117 16 4-20 ansi/jpi-600lb 3/4b 82.5 ? 51 56 51 56 55 60 55 60 34.9 42.9 34.9 42.9 34.9 42.9 ? ? t n-? flange d, q 1500 e, r 3000 l, s 5000 table 1 jkm g1/2 17 8 a, s 1/2-14npt 16 5 b, t pg13.5 8 4.5 c, v m20 1.5 16 5 d, w 4th digit of the code symbols conduit conn. note) cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. 2-m8 12 electronics unit sensor unit outline diagram (unit:mm)
11 outline diagram (unit:mm) press. conn. ? 4 holes 9 dia. (102) 25 ?4 105 70 231 104 ?0 8 88 ?0 52.5 94.5 23 20 38 58 210 191 60 43 70 120 50 (27) 37 s k 17 m ?5 j ?3 g1/2 + + ck+ + ck long vent/drain plug (added specification) vent/drain plug mtg. pipe jis 50a (2b) u - bolt m8 zero adj. screw fastener (flameproof only) cable gland (option) note) ??conduit conn. earth terminal ??conduit conn. with field ind. detail ? detail ? connection diagram in case of 4th digit code ? in case of 4th digit code ?.b.c.d.e up down 105 10 in case of 4th digit code ?.v.w.x 16th digit of code symbols 17th digit of code symbols press. conn. ? sr rc 1/2 sn 1/2-14npt s2 rc 3/4 st 3/4-14npt 11th digit of code symbols capillary length [mm] d, q 1500 e, r 3000 l, s 5000 table 1 jkm g1/2 17 8 a, s 1/2-14npt 16 5 b, t pg13.5 8 4.5 c, v m20 1.5 16 5 d, w 4th digit of the code symbols conduit conn. note) cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. 2-m8 12 electronics unit sensor unit
fkw ... 4 information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDSX5-82K

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X